BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Duncan Supply - ECPv6.15.15//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Duncan Supply
X-ORIGINAL-URL:https://duncansupply.com
X-WR-CALDESC:Events for Duncan Supply
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Indiana/Indianapolis
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20180311T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20181104T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20190310T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20191103T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20200308T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20201101T060000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/Indiana/Indianapolis:20190328T083000
DTEND;TZID=America/Indiana/Indianapolis:20190328T150000
DTSTAMP:20260411T131110
CREATED:20190304T135932Z
LAST-MODIFIED:20190304T135932Z
UID:2062-1553761800-1553785200@duncansupply.com
SUMMARY:Core Refrigeration - Champaign
DESCRIPTION:Core Refrigeration \nwith Mike Prokup \nThursday March 28th\nClass: 8:30am – 3:00pm \nClick Here to Register \nNote: This course allows for 5 hours toward NATE re-certification \nThis course will cover: \n\nAir properties and their influence upon the refrigeration system\nWhy evaporator coil matches are critical\nHow to calculate the theoretical capacity of a saturated refrigeration cycle\nHow suction pressure and discharge pressure changes affect the system capacity\nHow TXV metering provides better overall control\nHow suction lines drop system capacity\nTroubleshooting the evaporator circuit using suction vapor superheat measurements\nIdentifying metering piston problems\nDiagnostic test procedure: TXV and EEV\nSuction line sizing procedures\nTroubleshooting condenser coil circuits including parallel and subcooling loops\nLiquid subcooling levels\nLiquid line sizing\, lift and distance limits\nPressure drop limits and identifying restrictions\nCharge procedures for fixed and TXV systems\nAnalyzing the complete system & making a confident diagnosis\nEvacuation procedure
URL:https://duncansupply.com/event/core-refrigeration-indianapolis-copy/
LOCATION:Holiday Inn Champaign Suites\, 101 Trade Center Drive\, Champaign\, IL\, 61820\, United States
CATEGORIES:HVAC Training
END:VEVENT
END:VCALENDAR