BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Duncan Supply - ECPv6.15.15//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://duncansupply.com
X-WR-CALDESC:Events for Duncan Supply
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Indiana/Indianapolis
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20180311T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20181104T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20190310T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20191103T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20200308T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20201101T060000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/Indiana/Indianapolis:20190501T083000
DTEND;TZID=America/Indiana/Indianapolis:20190501T150000
DTSTAMP:20260410T010724
CREATED:20190304T135937Z
LAST-MODIFIED:20190304T135937Z
UID:2063-1556699400-1556722800@duncansupply.com
SUMMARY:Core Refrigeration - Warsaw
DESCRIPTION:Core Refrigeration \nwith Mike Prokup \nWednesday May 1st\nClass: 8:30 am – 3:00 pm \nClick Here to Register \nNote: This course allows for 5 hours toward NATE re-certification \nThis course will cover: \n\nAir properties and their influence upon the refrigeration system\nWhy evaporator coil matches are critical\nHow to calculate the theoretical capacity of a saturated refrigeration cycle\nHow suction pressure and discharge pressure changes affect the system capacity\nHow TXV metering provides better overall control\nHow suction lines drop system capacity\nTroubleshooting the evaporator circuit using suction vapor superheat measurements\nIdentifying metering piston problems\nDiagnostic test procedure: TXV and EEV\nSuction line sizing procedures\nTroubleshooting condenser coil circuits including parallel and subcooling loops\nLiquid subcooling levels\nLiquid line sizing\, lift and distance limits\nPressure drop limits and identifying restrictions\nCharge procedures for fixed and TXV systems\nAnalyzing the complete system & making a confident diagnosis\nEvacuation procedure
URL:https://duncansupply.com/event/core-refrigeration-indianapolis-copy-2/
LOCATION:Wyndham Garden Warsaw\, 2519 E. Center St.\, Warsaw\, 46580
CATEGORIES:HVAC Training
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/Indiana/Indianapolis:20190501T110000
DTEND;TZID=America/Indiana/Indianapolis:20190501T140000
DTSTAMP:20260410T010724
CREATED:20190221T091803Z
LAST-MODIFIED:20190221T091803Z
UID:2006-1556708400-1556719200@duncansupply.com
SUMMARY:Spectroline Counter Day - Bloomington
DESCRIPTION:
URL:https://duncansupply.com/event/spectroline-counter-day-bloomington/
LOCATION:Bloomington Branch\, 1204 N Loesch Rd\, Bloomington\, IN\, 47404\, United States
CATEGORIES:Counter Days
END:VEVENT
END:VCALENDAR